High Performance Galvanometer Scanners with 10mm mirrors
+
  • High Performance Galvanometer Scanners with 10mm mirrors

Product Features

■ Manufactured in China in accordance with ISO 9001 standards.

■ Galvanometer scanners are available in a variety of sizes and configurations.

■ Durable and suitable for diverse applications, ensuring reliable and error-free performance during long-term, continuous operation.

Technical Parameters

Motor Parameter
Model

1451

1403

1603

7220

MT1440

2206

Mirror Aperture Size(mm)

10

10~14

Mechanical Scan Angle(°)

±11

Rotor Inertia(g*mm^2,±10%)

20.4

19.9

20.01

27.8

14.651

43.88

Coil Resistance(Ω,±10%)

2.7

2.53

2.7

2.83

2.48

1.2

Coil Inductance(μH,±10%)

167.18

167.18

150.9

166.02

179.4

180.4

Peak Current(A)

6.56

6.56

3.78

3.74

4

3.56

Average current(A)

0.35

0.35

0.28

0.33

0.33

0.29

Step response time (1% of full scale)

10mm mirror

400μs

340μs

370μs

260μs

400μs

400μs

Weight(g)

44

44

56

198

36.3

123

Position Sensor
Linearity(@25℃)

99.9%

Repeatability (Short-Term)

8μrad

Gain error

≤5mrad

Zero Drift

≤15μrad/℃

Scale Drift

≤40ppm/℃

 

Keywords: High Performance Galvanometer Scanners with 10mm mirrors

High Performance Galvanometer Scanners with 10mm mirrors
+
  • High Performance Galvanometer Scanners with 10mm mirrors

High Performance Galvanometer Scanners with 10mm mirrors

Manufactured in China in accordance with ISO 9001 standards, our galvanometer scanners are available in a variety of sizes and configurations, delivering durable, reliable, and error-free performance for long-term continuous operation across diverse applications.

Classification


High Performance Galvanometer Scanners with 10mm mirrors
+
  • High Performance Galvanometer Scanners with 10mm mirrors

Product Features

■ Manufactured in China in accordance with ISO 9001 standards.

■ Galvanometer scanners are available in a variety of sizes and configurations.

■ Durable and suitable for diverse applications, ensuring reliable and error-free performance during long-term, continuous operation.

Technical Parameters

Motor Parameter
Model

1451

1403

1603

7220

MT1440

2206

Mirror Aperture Size(mm)

10

10~14

Mechanical Scan Angle(°)

±11

Rotor Inertia(g*mm^2,±10%)

20.4

19.9

20.01

27.8

14.651

43.88

Coil Resistance(Ω,±10%)

2.7

2.53

2.7

2.83

2.48

1.2

Coil Inductance(μH,±10%)

167.18

167.18

150.9

166.02

179.4

180.4

Peak Current(A)

6.56

6.56

3.78

3.74

4

3.56

Average current(A)

0.35

0.35

0.28

0.33

0.33

0.29

Step response time (1% of full scale)

10mm mirror

400μs

340μs

370μs

260μs

400μs

400μs

Weight(g)

44

44

56

198

36.3

123

Position Sensor
Linearity(@25℃)

99.9%

Repeatability (Short-Term)

8μrad

Gain error

≤5mrad

Zero Drift

≤15μrad/℃

Scale Drift

≤40ppm/℃

 

Keywords: High Performance Galvanometer Scanners with 10mm mirrors

Get a quote

Please leave your contact information, and our experts will reach out to you as soon as possible!

Submit