Products
HP 30-4000E High Power Galvo Scanner
HP30-4000E high power galvanometer scanners have the good running stability,strong anti-interference ability and it can be applied to continuous fiber lasers within 4000W. According to the divergence angle parameters of the laser, the corresponding QBH beam expanding collimator components and quartz field lens can be configured.
The specific characteristics of the galvanometer are as follows:
■ It adopts photoelectric sensors imported from the United States and has independent intellectual property rights.
■ Differential photoelectric sensor accurately detects the position of the motor rotor, with good linearity, small drift, high resolution and repeat positioning accuracy.
■ Accurate load design for 30mm lens, high precision motor assembly, reasonable structure, small static friction coefficient and small zero offset, to ensure the best dynamic characteristics of the system.
■ The driver has a position and speed advanced detection function, which greatly improves the dynamic response performance and scanning speed of the entire system.
■ It is designed with overload, over current and reverse connection protection to make the system operation more reliable.
■ The whole system adopts electromagnetic compatibility optimization design, with high signal-to-noise ratio and strong anti-interference ability.
HP30-4000E Technical Parameters
Precision and Error |
|
Step Response Time(1% of full scale) |
1512us |
Step Response Time(10% of full scale) |
1896us |
Tracking Error Time |
≤616us |
Linearity |
99.9% |
Gain Error |
<5mRad |
Zero Offset |
<5mRad |
Long-term Drift Over 8 Hours |
<0.5mRad |
Scale Drift |
<40PPM/℃ |
Zero Drift |
<15μRad/℃ |
Laser Matching |
|
Maximum CW Fiber Laser Power |
4000W |
Reflection Wavelength of Lens |
1064~1080nm (High power coating) |
Water cooling control |
|
Water Temperature |
25±3℃ |
Maximum Water Pressure |
<3bar |
Flow |
>1L/min |
Water Pipe Specifications |
Outer Diameter Φ6mm Inner Diameter Φ4mm |
Power and Signal |
|
Input Voltage |
±24VDC |
Rated Current |
4A |
Interface Signal |
XY2-100 |
Machinery Scan Angle |
±11° |
Working Current, Temperature, Dimension |
|
Working Temperature |
0℃~45℃ |
Storage Temperature |
-10℃~60℃ |
Aperture |
30mm |
Galvanometer Scanner Dimension (LxWxH) |
519.76×256.75×240.38mm |
Galvanometer Scanner Weight |
≈11.4kg |