RF8330-3D-1200 Dynamic focusing scanning system has good running stability, high positioning accuracy, higher marking speed, and strong anti-interference ability. In the process of dynamic marking, the marking line has high precision, distortion free, power uniform; pattern without distortion, the overall performance has reached the international leading level in the field. 



The advantages are as following:

 Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.

 Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning. 

 Adopted MM3D/Marking Mate 3D software system to support a variety of file formats, vector, bitmap and text bar code import, which is easy to learn and operate.

 Maximum working range 1200×1200mm, it is customizable for any printing field from 300×300mm to 1200mm×1200mm.

 Accurate load design for 30 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.

 Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.

 The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.

 This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.



RF8330-3D-1200 Technical Parameters

Laser Type

10600nm RF CO2 laser source

Printing Field

300×300mm~1200×1200mm

Input Beam Size

2.5~3mm

X&Y Axes Mirrors   Aperture Size

30mm

Speed

Marking Speed

1000mm/s

Positioning Speed

1000mm/s

Writing Speed

125cps

Step Response Time(1% of   full scale)

940us

Step Response Time(10% of   full scale)

1500us

Tracking Error Time

≤440us

Precision and Error

Linearity

99.9%

Repeatability (RMS)

8μRad

Gain Error

5mRad

Zero Offset

5mRad

Long-term Drift Over 8   Hours

0.5mRad

Scale Drift

40PPM/

Zero Drift

15μRad/

Power and Signal

Input Voltage

±24VDC

Rated Current

4A

Interface Signal

Digital

XY2-100

Machinery Scan Angle

±12.5°

Working Current, Temperature, Dimension

Working Temperature

0~45

Storage Temperature

-10~60

Galvanometer Scanner   Dimension

556.5×158×188mm   (L×W×H)

Galvanometer Scanner   Weight

≈16.78Kg

<<Back