Products

Home > Products

SG8214-G

Release time:2023-04-17 17:16  

The model SG8214-G galvo scanner has the good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, the overall performance of SG8214-G has reached the international leading level in this field.






The advantages are as following:


 Adopted the photoelectric sensors which imported from America, and owned the proprietary intellectual property rights.


 Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.


 Accurate load design for 14 mm mirrors, high accuracy of motor assembly, reasonable structure, very small static friction coefficient and zero offset, all ensured the best dynamic characteristics for the whole system.


 Drives with advanced detection ability of position and speed, greatly improved the dynamic response performance and scanning speed of the whole system.


 Design of overload, over-current and reverse connect protection, makes the system running more reliable.


 The whole system adopted the optimization Designing of electromagnetic compatibility, with high signal-to-noise

ratio and strong anti-interference ability.

 This scanner system solved the common problems of motor temperature drift, signal interference and zero drift, etc.



        

SG8214-G Technical Parameters:




Speed

Marking Speed(1)

8000mm/s

Writing Speed(2)

364cps

Step Response Time(1% of   full scale)

508us

Step Response Time(10% of   full scale)

820us

Tracking Error Time

360us

Precision and Error

Linearity

99.9%

Repeatability (RMS)

8μRad

Gain Error

5mRad

Zero Offset

5mRad

Long-term Drift Over 8   Hours

0.5mRad

Scale Drift

40PPM/℃

Zero Drift

15μRad/

Wavelength(3)

10600nm/1064nm/355nm

Power and Signal

Input Voltage

±24VDC

Rated Current

4A

Interface Signal

Digital

XY2-100

Analog

±5V

Machinery Scan Angle(4)

±12.5°

Working Current, Temperature,   Dimension

Working Temperature

0--45

Storage Temperature

-10--60

Aperture

14mm

Galvanometer Scanner   Dimension (LxWxH)

174.5*120*127mm

Galvanometer Scanner   Weight


≈4Kg                


Note: The above data are tested after 30 min warm-up

(1) With F-theta objective, F=160mm, marking 2mm height single character

(2) With F-theta objective, F=160mm, marking 1mm height single character per second

     (3)The standard mechanical scanning angle is ±12.5°.Other special requirement is available to be customized.

<<Back